THE AUDITORY MODELING TOOLBOX

Applies to version: 0.9.5

View the code

Go to function

DBSPL - RMS value of signal (in dB)

Usage

y = dbspl(insig);
y = dbspl(insig,'ac');

Description

dbspl(insig) computes the average SPL (sound pressure level) of the input signal measured in dB, using the convention that a pure tone at 100 dB SPL has an RMS value of 1.

dbspl(insig,'dboffset',dboffset) specifies a reference level to convert between RMS and dB SPL. Default value is 100. Some commonly used values are:

  • \(dboffset = 0\) . This convention was used for the development of the DRNL and Breebaart models.
  • \(dboffset = -20*log10(20e-6) = 93.98\) . This corresponds to the common convention of the reference being 20 micro Pa. Using this convention, the numerical values of signals is the sound pressure measured in Pascal.
  • \(dboffset = 100\) . This convention was used for the development of the Dau and Jepsen models.

Globally changing the reference level for all functions in the toolbox can be done by the following code:

ltfatsetdefaults('dbspl','dboffset',desired_dboffset);

and the currently used reference level is obtained by:

current_dboffset = dbspl(1);

DBSPL takes the following flags at the end of the line of input parameters:

'ac' Consider only the AC component of the signal (i.e. the mean is removed).
'dim',d Work along specified dimension. The default value of [] means to work along the first non-singleton one.
'dboffset',dboffset Specify offset in dB. Default value is 100.

References:

B. C. J. Moore. An Introduction to the Psychology of Hearing. Academic Press, 5th edition, 2003.