BAUMGARTNER2014_CALIBRATION - Calibration of the model

Usage

scalib = baumgartner2014_calibration(s)

Input parameters

s strucure containing subject's data. It must include the fields Obj, pe_exp, and qe_exp, representing the listener's HRTF as SOFA object, the baseline local polar RMS error, and the baseline quadrant error rate, respectively. Optionally, the structure can include the field target, a cell array representing the polar target angles for each lateral segment.

Output parameters

scalib strucure containing subject's data with calibrated S

Description

baumgartner2014_calibration returns listener data with listener-specific sensitivity thresholds calibrated by joint optimization of PE and QE to minimize mismatch between experimental and predicted results.

baumgartner2014_calibration accepts the following optional parameters:

'kv' Key-value pairs according to baumgartner2014
'TolX' Optimization tolerance of listener-specific sensitivity. Default is 1e-3.