This documentation page applies to an outdated major AMT version. We show it for archival purposes only.
Click here for the documentation menu and here to download the latest AMT (1.6.0).
[mp,fc] = baumgartner2014_spectralanalysis(sig)
sig | incoming time-domain signal |
mp | spectral magintude profile |
fc | center frequencies of auditory filters |
baumgartner2014_spectralanalysis(...) computes temporally integrated spectral magnitude profiles.
baumgartner2014_spectralanalysis accepts the following optional parameters:
'flow',flow | Set the lowest frequency in the filterbank to flow. Default value is 700 Hz. |
'fhigh',fhigh | Set the highest frequency in the filterbank to fhigh. Default value is 18000 Hz. |
'fs',fs | Define the sampling rate of the impulse responses. Default value is 48000 Hz. |
'space',sp | Set spacing of auditory filter bands (i.e., distance between neighbouring bands) to sp in number of equivalent rectangular bandwidths (ERBs). Default value is 1 ERB. |
R. Baumgartner, P. Majdak, and B. Laback. Modeling sound-source localization in sagittal planes for human listeners. The Journal of the Acoustical Society of America, 136(2):791--802, 2014. [ DOI ]