THE AUDITORY MODELING TOOLBOX

Applies to version: 1.5.0

View the code

Go to function

eurich2022_decision - Decision stage of the Eurich et al. (2022) model

Usage:

dprime = eurich2022_decision(processed,mpar)

Input parameters:

processed Matrix containing the processed stimulus from eurich2022_processing
mpar
Structure with the following model parameters:
  • fs: sampling frequency of model
  • Filters_per_ERB_aud: spacing of peripheral filter central frequencies in ERB
  • GT_bandwidth_factor: factor of gammatone filter bandwidth relative to "standard" (i.e. ERB = 79 Hz @500Hz)
  • GT_lowest_center_frequency: lower bound of gammatone filterbank
  • GT_highest_center_frequency: higher bound of gammatone filterbank
  • GT_fix_center_frequency: fixed center frequency of one of the gammatone filterbank's filters
  • GT_filterorder: filter order of gammatone filterbank
  • interference_sigma: std of the Gaussian window used for the across-frequency incoherence interference
  • iKernelThresh: threshold above which a value of the Gaussian filter window is used
  • rho_max upper limit of encoded interaural coherence (i.e. internal noise)
  • monaural_internal_noise_sigma: std of the Gaussian, level-dependent internal noise of the monaural feature
  • binaural_internal_noise_sigma: std of the Gaussian internal noise of the binaural feature
  • target_channel: index of the channel to be selected for processing in eurich2022_decision

Output parameters:

dprime combined sensitivity indices of binaural and monaural feature

References:

B. Eurich, J. Encke, S. D. Ewert, and M. Dietz. Lower interaural coherence in off-signal bands impairs binaural detection. The Journal of the Acoustical Society of America, 151(6):3927--3936, 06 2022. [ DOI | .pdf ]